4. Existing Masonry Chimney

Co-Axial to
Co-Linear Connector
Pipe Length
Optional
Type C - Up & Out Installation
TOP ADAPTOR
RETRO
CONNECTOR
90° ELBOW
DIRECT
VENT PIPE
Figure 5.24
Type A & B Co-Axial to Co-Linear
Chimney Liner
Termination Cap
3 in. (76mm)
Flex Liner
Showing two
30 ft.
(9m)Sections
of Flex Liner
TERMINATION
CAP
FLASHING
4 in. (102mm)
FLEX LINER
Heat & Glo • TIARA II-B • 7011-148 Rev. D • 12/11
Co-Axial to Co-Linear
Connector
Pipe Length
Optional
*NOTE: In the Commonwealth of Massachusetts, the word damper shall
be replaced with the words fl ue restrictor.
Type D - Hearth Mount
Alcove Clearance to
Combustibles must be
maintained
Co-Axial to Co-Linear Connector
*NOTE: In the Commonwealth of Massachusettes, the word damper shall
be replaced with the words fl ue restrictor.
Chimney Liner
Termination Cap
30 ft. (9m) of 3 in.
(76mm) Flex Liner
Exhaust Section
This section of the
chimney must be
sealed
The chimney must be
sealed from the 4 ft. (1m)
section to termination
using a smoke shelf or a
damper*. The seal
should be 6 in. (152mm)
below the end of the 4 ft.
(1m) Air Intake section.
4 ft. (1m) of 3 in. (76mm)
Flex Liner Air Intake Section
Chimney Liner
Termination Cap
30 ft. (9m) of 3 in. (76mm)
Flex Liner Exhaust Section
This section of the
chimney must be sealed
Chimney must be sealed
from 4 ft. (1m) section to
termination using a smoke
shelf or a damper*. Seal
should be 6 in. (152mm)
below end of 4 ft. (1m) Air
Intake section.
4 ft. (1m) of 3 in.
(76mm) Flex Liner
Air Intake Section
19