Heat & Glo Pier-HVB-IPI Owner's Manual
Hide thumbs Also See for Pier-HVB-IPI:

Advertisement

Models:
Pier-HVB-IPI
ST-HVB-IPI
LCOR-HVB-IPI
RCOR-HVB-IPI
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
-
What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Printed in U.S.A. Copyright 2006
Heat & Glo, a brand of Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471,
5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165,
6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802,
6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250,
780403, 1418504 or other U.S. and foreign patents pending.
Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06
Owner's Manual
Installation and Operation
WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
1. This appliance may be installed in an af-
termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed
plumber or gas fitter;
• a CO detector shall be installed in the room
where the appliance is installed.
Please contact your Heat-N-Glo dealer with any
questions or concerns. For the number of your nearest
Heat-N-Glo dealer, please call 1-888-427-3973.
Underwriters
Laboratories Listed
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo Pier-HVB-IPI

  • Page 1 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 2: Safety And Warning Information

    DO NOT place furniture or any other combustible Young children should be CAREFULLY SUPERVISED household objects within 36 inches of the fireplace when they are in the same room as the appliance. front. Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 3: Table Of Contents

    Step 11. Before Lighting the Fireplace ............40 Step 12. Lighting the Fireplace ..............40 After the Installation ..................40 Maintaining and Servicing Your Fireplace ........ 41 = Contains updated information. Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 4: Approvals And Codes

    Code (in Canada). These models may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada. Heat & Glo Quality Systems registered by SGS ICS Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 5: Getting Started

    Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 6 (114mm) TOP VENT COLLARS TOP STANDOFFS REAR VENT COLLARS SIDE GLASS DOOR GAS CONTROLS & LABELS GAS LINE ACCESS ELECTRICAL ACCESS Figure 1. Diagram of the PIER-HVB-IPI Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 7 (121mm) TOP VENT COLLARS TOP STANDOFFS REAR VENT COLLARS GAS CONTROLS SIDE GLASS & LABELS DOOR GAS LINE ACCESS ELECTRICAL ACCESS Figure 2. Diagram of the ST-HVB-IPI Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 8 COLLARS REAR VENT COLLARS SIDE GLASS DOOR END GLASS GAS LINE DOOR ACCESS GAS CONTROLS & LABELS ELECTRICAL ACCESS Figure 3. Diagram of the LCOR-HVB-IPI and RCOR-HVB-IPI Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 9: Installing The Fireplace

    The minimum clearance to a perpendicular wall extending past the face of the fireplace is one inch (25 mm). The metal ends of the fireplace may NOT be recessed into combustible construction. Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 10: Step 2. Framing The Fireplace

    Bottom ......1/2 ....13 Sides ......... 1 ....25 For minimum clearances, see the direct vent termination clearance diagrams on pages 31 and 32 in this manual. Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 11 ST-HV-IPI L & R-COR-HV-IPI Model PIER-HVB-IPI 42-1/8 42-1/2 35-3/4 ST-HVB-IPI 47-5/8 42-1/2 35-3/4 L&RCOR-HVB-IPI 42-1/8 42-1/2 28-3/4 35-3/4 NOTE: DIMENSIONS SHOWN IN INCHES Figure 5. Framing Dimensions Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 12 DVP48 1/2 TYP 8-9/16 12-9/16 NOTE: PIPES OVERLAP 1-1/4 INCHES AT EACH JOINT. Figure 6. DVP-Series Direct Vent Component Specifications (5-inch inner pipe / 8-inch outer pipe) Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 13: Step 3. Installing The Vent System

    DVP-TV DVP-TRAP DVP-TB1 DVP-TVHW SERIES (Required to have a minimum of 3 feet of vertical in the vent system) Figure 7. Vent System Components and Termination Kits Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 14 Figure 9 2. Break the Flue Restrictor into two pieces. Do this by bending the part back and forth until it breaks Figure 12. (see Figure 10). Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 15 6’ MIN. (1.83m) 12' MAX. (3.6m) V + H = 50’ MAX. (15.2m) V + H = 50’ MAX. (15.2m) Figure 14. Venting with One 90° Elbow Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 16 5’ MIN. (1.5m) 10' MAX. (3.0m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V + V + H = 50’ MAX. (15.2m) Figure 15. Venting with Two 90° Elbows Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 17 V + H + H = 50’ MAX. (15.2m) H + H = 18’ MAX. (5.5m) H + H = 12’ MAX. (3.6m) Figure 17. Venting with Two 90° Elbows Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 18 + H + H = 50’ MAX. (15.2m) H + H = 18’ MAX. (5.5m) H + H = 12’ MAX. (3.6m) Figure 18. Venting with three 90° elbows Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 19 12' MAX. (3.6m) + H + H = 50’ MAX. (15.2m) V+ V H + H = 12’ MAX. (3.6m) Figure 19. Venting with three 90° elbows Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 20: Installing Vent Components

    If the installation is for a termination cap attached directly to the fireplace, skip to the sections, Install Firestops and ELBOW Vent Termination. ELBOW SEAM FRONT VIEW Figure 21 TOP VIEW Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 21 HOLE INTERIOR WALL SHIELD EXISTING CEILING JOISTS FRAMING MEMBERS CEILING 12" Figure 25 Hole & New Framing Members Figure 23. 10" x 12" Hole and Vent Pipe Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 22: Vent Termination

    NOTE: There must be NO INSULATION or other combustibles inside the framed firestop opening. NAILS (4 REQUIRED) RAFTER 7 1/4" (184mm) Figure 28. Trapezoid Termination Cap CEILING CEILING FIRESTOP Figure 27. Attic Firestop Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 23 Figure 29. Vent Termination Minimum Clearances CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 24 12/12 to 14/12 over 14/12 to 16/12 over 16/12 to 18/12 over 18/12 to 20/12 over 20/12 to 21/12 Figure 30. Minimum Height from Roof to Lowest Discharge Opening Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 25: Step 4. Positioning, Leveling, And Securing The Fireplace

    • Secure the fireplace to the framing by nailing or screwing. • Holes are provided in the base pan for securing the unit to the floor. Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 26: Step 6. The Gas Supply Line

    (1/2) psig (3.5 kPa). Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 27: Step 8. Wiring The Fireplace

    • Uninterrupted or continuous power is required at all times in IPI system EXCEPT when using battery back-up. • Incorrect wiring will override IPI safety lockout and may cause explosion. Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 28 This will provide the shown. This will provide the best air flow (see Figure 36). best air flow (see Figure 37). Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 29: Step 9. Finishing

    12” HOOD CLIP HOOD NOTE: 12” mantel at 23” above hood. Minimum Vertical and Maximum Horizontal Figure 39. Dimensions of Combustibles above Fireplace Figure 41. Hood Clip Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 30: Step 10. Installing Trim, Logs & Ember Material

    If sooting occurs, the logs might need to be repositioned slightly to avoid excessive flame impingement. Shutter Settings ___________________________________________ PIER-HVB-IPI 3/8” FULL OPEN ___________________________________________ ST-HVB-IPI 3/8” FULL OPEN ___________________________________________ L&RCOR-HVB-IPI 3/8” FULL OPEN Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 31: Placing The Ember Material

    Any skin oils which get on a new bulb will greatly shorten the life of the bulb. The bulb can be cleaned with isopropyl alcohol (see Figure 45). Figure 45. Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 32: Step 11. Before Lighting The Fireplace

    • Any component that is found to be faulty MUST BE re- placed with an approved component. Tampering with the fireplace components is DANGEROUS and voids all war- ranties. Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...
  • Page 33: Maintaining And Servicing Your Fireplace

    Make sure the flames are steady - not lifting or floating. See Figure 47. The flame sensor (IPI) tips should be covered with flame. See Figure 32. Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI • 2006-900 Rev. M• 8/06...