TRANSFORMER
ON/OFF
WALL
SWITCH
NEUTRAL
Figure 7.2
CAUTION
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
D. Loss of Power and Battery Backup Usage
1. Disconnect the power supply.
2. Remove the front door assembly and lower access
panel.
3. Place two "D" cell batteries into the battery holder.
(Figure 7.3)
4. Turn on appliance and verify it is operational.
5. Replace lower access panel and front door assembly.
CAUTION
If IPI battery back-up is installed:
• Do not install batteries if the backup mode may not be used
for extended time.
• Batteries may leak.
• Install batteries only when needed for power outage.
PLUG-IN 3V
IGNITION
MODULE
(3V)
VALVE
REMOTE
CONTROL
HOT
GROUND
PLUG IN
JUNCTION BOX
Heat & Glo • Paloma • 7031-220 Rev. P • 10/08
IGNITION MODULE
3 VAC
FLAME
SPARKER/SENSOR
BATTERY
PACK
APPLIANCE CHASSIS
RED
PIGGYBACK
ON/OFF SWITCH
TRANSFORMER
3 VAC
NOTE: Appliance will not operate
unless properly grounded.
Figure 7.3
I
INTERMITTENT
PILOT IGNITOR
S
WHT
ORG
GROUND TO
*
VALVE
WARNING
Shock hazard.
• Replace damaged wire with type 105º C rated
wire.
• Wire must have high temperature insulation.
Unplug when
using batteries
BATTERY LOCATION