Replenishing the coolant
WARNING
@
G
Do not remove the coolant reservoir cap when
the engine is hot. Scalding hot fluid and steam
may be blown out under pressure, which could
cause serious injury.
When the engine has cooled, place a thick rag or
towel over the coolant reservoir cap, and slowly
rotate the cap counterclockwise to the detent.
This procedure allows any residual pressure to
escape. When the hissing sound has stopped,
press down on the cap while turning counter-
clockwise and remove it.
G
The cooling system must be bled of air if the
coolant reservoir becomes empty, if air can be
seen in the cooling system, or if there is a cooling
system leak. Consult a Yamaha dealer.
@
1. Remove the top cover and the right upper cover (for
PZ50FX/PZ50GT/PZ50M), or open the shroud and
remove the right upper cover (for PZ50VT). (See
pages 8-6–8-9 for removal procedures.)
2. Remove the coolant reservoir cap, add the recom-
mended coolant until it reaches the "COLD LEVEL"
mark, and then install the cap.
Recommended coolant:
High quality ethylene glycol antifreeze containing cor-
rosion inhibitors
Antifreeze and water mixing ratio:
60:40
Total amount:
For PZ50FX/PZ50GT/PZ50M
3.6 L (3.17 Imp qt, 3.81 US qt)
For PZ50VT
3.7 L (3.26 Imp qt, 3.91 US qt)
1 "COLD LEVEL" mark
2 Coolant reservoir cap
3. Start the engine, allow it to idle for several minutes,
and then turn it off.
4. Check for any coolant leakage.
8-16