Connections
In this type of installation, only one Video Multi-
plexer is connected directly to the System
Controller by a control cable.
The rest of the Video Multiplexers are connected to
the system Controller in a daisy-chain type connec-
tion.
Refer to the connections and data port settings
shown below.
Local Site
Video Multiplexer
WJ-FS616
SPOT
OUT
I N
OUT
DATA
OUT
IN
TEAM.
OFF
ON
Notes:
• Up to four Video Multiplexers can be daisy-
chained to the System Controller.
• Unit numbers should be assigned in the order
of connection, starting with the unit connected
directly to the WV-CU550A System Controller.
• It is not available to activate sequence extend-
ed the unit.
• It is recommended to set the LOCK switch to
the ON position while making these connec-
tions.
• For controlling more than 4 cameras, additional
WV-PB6164 Data Multiplex Board should be
installed in the Video Multiplexer.
Operating Procedures
1. Confirm that the camera and peripherals are con-
nected correctly and firmly.
2. Turn on the power switches of all system compo-
nents.
3. Confirm that the DAISY MODE parameter on the
SYSTEM SETUP menu is set to ON.
4. Select the unit number of the Video Multiplexer with
the Numeric Keys. Then press the UNIT/ESC key to
activate the selected unit.
1
2
4
5
7
8
0
MON
UNIT/ESC
Main Site
Video Multiplexer
WJ-FS616
SPOT
I N
DATA
DATA
OUT
IN
IN
OUT
TEAM.
OFF
ON
TERM
ON
OFF
3
6
9
CAM
SET
For example, press the keys shown below.
2
In this example, the picture of Camera No. 15 con-
nected to Video Multiplexer the Unit 2 is displayed
on the Spot Monitor connected to Video Multiplexer
the Unit 1.
5. Operate the selected unit as described in the
OPERATING PROCEDURES.
6. Select another unit with the Numeric Keys. Then
press the UNIT/ESC key to activate the selected
unit.
CONTROLLER
UNIT NO.
1-8
0
5
Other Application
The video signal looped through the SPOT IN con-
nector can be displayed on the Spot Monitor.
VIDEO
Unit
2
1. Confirm that the LINK parameter on the SYSTEM
SETUP menu is set to DAISY MODE.
2. Select the unit number of the Video Multiplexer with
the Numeric Keys. Then press the UNIT/ESC key to
activate the selected unit.
3. Press the (F2) button on the controller to select the
spot monitor.
4. Press [ 0 ] then press the SET key to display the
video on the Spot Monitor looped through the SPOT
IN connector.
-53-
1
5
MON
CAM
UNIT/ESC
VIDEO