Panasonic WJ-FS616 Operating Instruction page 35

Video multiplexer
Hide thumbs Also See for WJ-FS616:
Table of Contents

Advertisement

Dwell Time
1. Move the cursor to the DWELL TIME parame-
ter.
2. Select the desired dwell time by pressing the
LEFT or RIGHT button.
Dwell Time can be selected between 0SEC
and 30SEC.
Note: If 0SEC is selected for dwell time, that
step will not be shown on the monitor
screen.
Display Channel Assignment
1. Move the cursor to the area number you want
to edit in the CAM area by pressing the
Direction Arrow buttons.
2. Select the desired camera or playback channel
in the CAM area by pressing the Increment (+)
or Decrement ( ) button.
3. Repeat the above procedures to assign other
area numbers.
Note:
The multiscreen pattern of each step is
determined automatically as follows:
First the highest area number to which a
channel is assigned is determined. Then a
screen segmentation that is higher than
that area number .... is selected.
Preset Position
1. Move the cursor to the area number you want
to edit in the PRE area by pressing the
Direction Arrow Buttons.
2. Select the desired preset position number in
the PRE area by pressing the Increment (+) or
Decrement ( ) button.
Notes:
• When the STEP parameter in this table is
on PLAY, it is not possible t select a preset
position in the PRE area.
• It is possible to assign the same camera
channel to multiple area numbers within a
step. In this case, make sure to assign the
same preset positions.
Programming Steps 2 to 5
1. Press the FUNCTION button to display the next
step.
2. Program the sequence pattern for steps 2 to 5
according to the procedures described above.
3. After
completing
SETUP/ESC button to execute the setting and
return to the previous SYSTEM SETUP menu.
the
setting,
press
the
6. Sequence Timing (Multiscreen)
This item lets you select functions of devices con-
nected to pin 26 of the ALARM/REMOTE Control
Connector.
One of these functions is input of the time adjust-
ment signal from a VTR, the other enables external
sequence switching for multiscreen output.
1. Move the cursor to the SEQ TIMING-MLT para-
meter.
2. Select INT(TIME-ADJ) or EXT by pressing the
LEFT or RIGHT button.
INT: Advances a sequence by the Dwell time
that was programmed on the SEQUENCE
SETUP menu.
It enables input the time adjustment signal
from a Time Lapse VTR.
EXT: Enables external sequence switching.
Notes:
• If EXT is selected, time adjustment input
from a Time Lapse VTR is disabled.
• If EXT is selected, connect the external
sequence
ALARM/REMOTE Control Connector.
7. Sequence Timing (Spot)
This item lets you select between internal and
external control for advancing the sequence on the
Spot Monitor.
1. Move the cursor to the SEQ TIMING-SPT para-
meter.
2. Select INT or EXT by pressing the LEFT or
RIGHT button.
INT: Advances a sequence by the Dwell Time
that was programmed on the SEQUENCE
SETUP menu.
EXT: Advances a sequence by the input from
pin 6 of the ALARM/REMOTE Control
Connector.
8. Lock Mode
This item lets you decide which buttons will be
locked while the LOCK switch is in ON position.
1. Move the cursor to the LOCK MODE parame-
ter.
2. Select ALL or VTR by pressing the LEFT or
RIGHT button. Initially, the initial factory setting
is ALL.
VTR: Locks the VTR Control Buttons.
ALL: Locks all the buttons.
Note: The LOCK indicator only lights up when
the LOCK switch is in ON position and
LOCK MODE is set to ALL.
-33-
switch
to
pin
26
of
the

Advertisement

Table of Contents
loading