Gas and electric dryer

Advertisement

Available languages

Available languages

GAS DR R
POWER
HOOKUP
ELECTRICAL
REQUIREMENTS
[]
Electrical
Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow
these instructions can result in death,
fire, or electrical shock.
120 Volt, 60 Hz, AC only, 15- or 20- amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended.
It is also recommended
that a separate
circuit serving only this dryer be provided.
GROUNDING
iNSTRUCTiONS
[] For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor
and a grounding plug. The plug must
be plugged into an appropriate
outlet that is properly
installed and grounded in accordance
with all local codes
and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE
INSTRUCTIONS
GAS SUPPLY REQUIREMENTS
Explosion Hazard
Use a new CSA International approved
gas supply line.
install a shut-off
valve.
Securely
tighten all gas connections.
If connected
to LP, have a qualified
person make sure
gas pressure
does not exceed 13" (330 ram} water
column.
Examples of a qualified
person
include:
licensed
heating
personnel,
authorized
gas company
personnel,
and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
GAS TYPE
Natural Gas:
This dryer is equipped for use with Natural gas. It is
design-certified
by CSA International for LP (propane or
butane) gases with appropriate
conversion.
[]
Your dryer must have the correct burner for the type of gas
in your home. Burner information
is located on the rating
plate in the door well of your dryer. If this information
does
not agree with the type of gas available, contact your dealer
or call the phone numbers referenced in the "Assistance
or
Service" section of your "Use and Care Guide."
LP Gas Conversion:
iMPORTANT:
Conversion must be made by a qualified
technician.
No attempt shall be made to convert the dryer from the gas
specified on the model/serial
rating plate for use with a different
gas without consulting your gas company.