Determine
vent path:
[] Select route that will provide straightest
and most direct
path outdoors.
[] Plan installation to use fewest number of elbows and turns.
[] When using elbows or making turns, allow as much room
as possible.
[] Bend vent gradually to avoid kinking.
[] Use as few 90 ° turns as possible.
Determine
vent length and elbows
needed
for best
drying
performance:
[] Use the following "Vent System Charts" to determine type of
vent material and hood combinations
acceptable to use.
NOTE: Do not use vent runs longer than those specified
in "Vent System Charts." Exhaust systems longer than those
specified will:
[] Shorten life of dryer.
[] Reduce performance,
resulting in longer drying times
and increased energy usage.
The "Vent System Charts" provide venting requirements that
will help achieve best drying performance.
Standard
Vent System
Chart
Number
of
Type
Box/Iouvered
Angled
90 ° elbows
of vent
hoods
hoods
0
Rigid metal
64 ft. (20 m)
58 ft. (17.7 m)
1
Rigid metal
54 ft. (16.5 m)
48 ft. (14.6 m)
2
Rigid metal
44 ft. (13.4m)
38 ft. (11.6m)
3
Rigid metal
35 ft. (10.7 m)
29 ft. (8.8 m)
4
Rigid metal
27 ft. (8.2 m)
21 ft. (6.4 m)
Long Vent System
Chart*
Number
of
90 ° elbows
0
1
2
3
4
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
*For Model WGD9051Y only.
Box/Iouvered
Angled
hoods
hoods
130 ft. (39.6 m)
129 ft. (39.3 m)
125 ft. (38.1 m)
119 ft. (36.3 m)
115 ft. (35.1 m)
109 ft. (33.2 m)
106 ft. (32.3 m)
100 ft. (30.5 m)
98 ft. (29.9 m)
92 ft. (28.0 m)
NOTE: Side and bottom exhaust installations have a 90 ° turn
inside the dryer. To determine maximum exhaust length, add one
90 ° turn to the chart.
12
INSTALL
¥_NT
SYSTE_
1,
Install exhaust hood
12" rain.
(305 ram)
Install exhaust hood and use caulking compound
to seal
exterior wall opening around exhaust hood.
2,
Connect
vent to exhaust
hood
Vent must fit over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location
using straightest
path possible. Avoid 90 ° turns. Use clamps
to seal all joints. Do not use duct tape, screws, or other
fastening devices that extend into interior of vent to secure
vent, because they can catch lint.
INSTALL
LE¥_LING
LEGS
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1.
Prepare dryer for leveling
legs
To avoid damaging floor, use a large flat piece of cardboard
from dryer carton; place under entire back edge of dryer.
Firmly grasp dryer body (not console panel) and gently lay
dryer down on cardboard.

Advertisement

loading