Set Calibration Factor Manually

The calibration factor is calculated as a ratio of the actual distance to the uncalibrated distance.
Example: you run 1200m, the training computer shows a distance of 1180m, the calibration factor is
1.000. Calculate the new calibration factor as follows: 1.000*1200/1180 = 1.017. The measuring
range for the factor is 0.500-1.500.
There are four options for setting the calibration factor:
1.
Before exercise.
Select
Settings > Features > Shoes/bikes > Shoe 1/2/3 > Calibrate
Set the
and press OK. The sensor is now calibrated.
Calibration factor
2.
After starting heart rate measurement and before exercise recording.
In time mode, select OK >
Set the
and press OK. The sensor is now calibrated, and you can start exercise
Calibration factor
recording by pressing OK.
3.
During exercise by pausing exercise recording.
Start exercising by pressing OK twice in the time display. Press STOP once and the exercise recording
is paused.
Select
Settings > Calibrate > Set factor
Set the
and press OK. The sensor is now calibrated. Continue exercise recording by
Calibration factor
pressing OK.
4.
During exercise without pausing exercise recording.
Start exercising by pressing OK twice in the time display. Press and hold LIGHT to get to
Select
Calibrate > Set factor
Set the
and press OK. The sensor is now calibrated. Continue running.
Calibration factor
If message
S sensor calibration failed
again.
*Optional s3 stride sensor W.I.N.D. required.

5 . T RAI NI NG

Wear the Transmitter

Wear the transmitter to measure heart rate.
Before starting training recording, you need to wear the WearLink.
1.
Wet the electrode areas of the strap well under running water.
We recommend using contact gel (ECG gel) to optimize contact between your skin and the transmitter,
especially during long-lasting events.
2.
Attach the connector to the strap. Adjust the strap length to fit tightly but comfortably.
3.
Tie the strap around your chest, just below the chest muscles, and attach the hook to the other
end of the strap.
4.
Check that the wet electrode areas are firmly against your skin and that the Polar logo of the
connector is in a central and upright position.
Settings > Shoes/bikes > Shoes 1/2/3 > Calibrate
.
.
is displayed the sensor has not been calibrated and you need to try
.
.
.
Settings