Battery Replacement - HP ProLiant DL G6 User Manual

Table of Contents

Advertisement

Battery replacement

If the server no longer automatically displays the correct date and time, you may need to replace the battery
that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.
WARNING:
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:
Do not attempt to recharge the battery.
Do not expose the battery to temperatures higher than 60°C (140°F).
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
Replace only with the spare designated for this product.
To remove the component:
Power down the server (on page 22).
1.
Extend or remove the server from the rack
2.
Remove the access panel (on page 25).
3.
Remove the PCI riser cage.
4.
CAUTION:
remove all AC power cords before removing or installing the expansion boards.
Remove the battery.
5.
IMPORTANT:
configuration. After replacing the battery, reconfigure the system through RBSU.
To replace the component, reverse the removal procedure.
The computer contains an internal lithium manganese dioxide, a vanadium
To prevent damage to the server or expansion boards, power down the server and
Replacing the system board battery resets the system ROM to its default
("Extend the server from the
rack" on page 24).