HP ProLiant DL G6 User Manual page 10

Table of Contents

Advertisement

Systems Insight Display
LED and color
Processor (amber)
Processor (amber)
DIMM (amber)
DIMM (amber)
Overtemperature (amber) Amber
Overtemperature (amber) Red
Fan (amber)
Fan (amber)
Power supply (amber)
Power supply (amber)
Power cap (off)
Power cap (green)
Power cap (flashing
amber)
Power cap (green)
IMPORTANT:
Test each bank of DIMMs by removing all other DIMMs. Isolate the failed DIMM by replacing
each DIMM in a bank with a known working DIMM.
Health LED
System power
LED
Red
Amber
Amber
Green
Red
Green
Amber
Green
Green
Amber
Amber
Green
Red
Green
Red
Amber
Amber
Green
Amber
Flashing green
Amber
Green
If more than one DIMM slot LED is illuminated, further troubleshooting is required.
Status
One or more of the following conditions may
exist:
Processor in socket X has failed.
Processor X is not installed in the socket.
Processor X is unsupported.
ROM detects a failed processor during
POST
Processor in socket X is in a pre-failure
condition.
One or more DIMMs have failed.
DIMM in slot X is in a pre-failure condition.
The Health Driver has detected a cautionary
temperature level.
The server has detected a hardware critical
temperature level.
One fan has failed or has been removed.
Two or more fans have failed or been
removed.
Only one power supply is installed and
that power supply is in standby.
Power supply fault
System board fault
Redundant power supply is installed and
only one power supply is functional.
AC power cord is not plugged into
redundant power supply.
Redundant power supply fault
Power supply mismatch at POST or
power supply mismatch through hot-plug
addition.
Standby
Waiting for power
Power cap has been exceeded
Power is available
Component identification 10