A_48
A_49
A_50
A_51
KD Workshop Manual_cod. ED0053029350_1° ed_ rev. 00
To assemble the phase sensor connector press the locking spring.
Remove the connector from the sensor.
Loosen screw M6. When refitting, tighten to 8 Nm.
Remove the sensor from the support taking care not to damage the
O-ring.
Disassembly / Reassembly
II
- 91 -