II
Disassembly / Reassembly
A_8
A_9
A_10
A_11
- 76 -
Components:
1 Variator load solenoid valve
2 Variator unload solenoid valve
Important
Do not invert cables during reassembly.
To remove connectors, press the stop tabs and draw upwards.
Refer to page 78 to identify the pipes.
Loosen the union screw of pipes 17 and 19.
On the opposite end of the block of pipe 19 is the variator lubrication
jet attached to the pipe by a click clamp.