- 26 -
Blower assembly components with 14 A alternator
1 Housing
2 14 A alternator
3 Key
4 Ball bearing
5 Washer
6 Nut
7 Shaft
8 Bolt
9 Fan
10 14 A alternator bell
11 Spacer
Blower assembly components with 21 A alternator
1 Housing
2 21 A alternator
3 Key
4 Washer
5 Nut
6 Shaft
7 Bearing
8 Bolt
9 Fan
10 21 A alternator bell
11 Spacer
Blower control pulley - Disassembly
The blower control pulley is installed on and is driven by the cran-
kshaft.
To disassemble the pulley unscrew the left-handed bolt (clockwise) af-
ter blocking the crankshaft.
When reassembling, tighten the bolt using a torque wrench to a
torque of 300 Nm.