4.9.11.

System Event

You can set event actions for disk, recording, network and system events. As same to setting event actions for normal
events, you can set to trigger alarm output, buzzer, display on-screen pop-up, or send event notification via email and
FTP.
1. From <SYSTEM SETUP> - <EVENT>, select <SYSTEM EVENT>.
2. Use the [▲▼◀▶] buttons on the remote control or use the mouse to specify the reaction to each event.
3. To apply the change, click <APPLY> in the bottom of the screen.
4. When done, press the [EXIT] button on the remote control or click <CLOSE> in the lower screen to return to the
previous menu.
4.9.12.

Disk

OVERWRITE START EVENT : if you set the disk write
mode to <OVERWRITE>, this event occurs when the
disk is full and the overwriting begins accordingly.
DISK FULL EVENT : if you set the disk write mode to
<ONCE>, this event occurs when the disk is full
(100%).
DISK SPACE EXHAUSTED EVENT : Event that is
triggered if the disk is almost full. Click to specify the
threshold percentage of usage to trigger the event.
S.M.A.R.T EVENT : Occurs if the disk causes the
S.M.A.R.T error.
NO DISK EVENT : Occurs if no disk is recognized after
the booting due to a disk failure or cable problem.
! To detect the disk error, it is recommended not to
change the settings of the S.M.A.R.T event, no disk event
and buzzer output.
4.9.13.

Record

PANIC RECORD START EVENT : Specify the action
to perform when the panic recording begins.