Typical Fireplace System - Heat & Glo LifeStyle RH-36 Series Owner's Manual

Woodburning
Table of Contents

Advertisement

C. Typical Fireplace System
The Heat & Glo fi replace system consists of the following:
Fireplace/integral grate/refractory
Chimney termination cap
Chimney system
Hearth extension
Optional components include:
Glass doors
Chimney air kit
Outside Air System
Additional lateral
support for chimney
above roof (or enclosed
in chase) if needed
Non-combustible
roof flashing maintains
minimum clearance
around chimney
Support straps
on rafter supports
chimney (not shown)
Ceiling firestop
on floor of attic
Chimney system
Combustible
framing/header
on top of
V-shaped
standoffs
(spacers)
Outside
combustion air
Figure 2.2

Typical Fireplace System

Protective metal
hearth strip(s)
Heat & Glo • RH-36/RH-42 • 4044-153 Rev S • 06/07
Termination cap
Storm Collar
Chimney penetrates roof
preferably without affecting
roof rafters
Offset/Return (with hanger straps)
Attic insulation shield (not shown) must
be used here to keep insulation away
from chimney if attic is insulated
Framing headed off
in ceiling joists
Enclosed space above
and around fireplace
Mantel and surround
Decorative facing
and trim
Hearth extension
Factory-built fireplace
7