Section 3: Installing The Fireplace; Step 1 Locating The Fireplace - Heat & Glo LifeStyle PIER-TVFL Installer's Manual

Table of Contents

Advertisement

3
Installing the
Fireplace
14
Step 1
Locating the
Fireplace
Minimum Clearances from the Fireplace to
Glass
Sides
Floor
36 inches
0
(914 mm)
The diagram below shows space and clearance
requirements for locating a fireplace within a room.
GLASS
36"
Figure 3.
Fireplace Locations and Space
Requirements
Clearance Requirements
The top, back, and sides of the fireplace are defined
by stand-offs.
Combustible Materials
Back of
Metal Ends
Fireplace
of Fireplace
1/2 inch
1/2 inch
(13 mm)
(13 mm)
*
The clearance to the ceiling is measured from the top of
the unit, excluding any standoffs (see Figure 13).
The minimum clearance to a perpendicular wall extending
past the face of the fireplace is one inch (25 mm).
The metal end(s) of these fireplaces may NOT be
recessed into combustible construction.
GLASS
GLASS
PIER-TVFL
36 "
TOP
VIEW
36"
ST-42TVFL
GLASS
1"
GLASS
Top of
Fireplace
Ceiling*
4-1/2 inches
31 inches
(89 mm)
(787 mm)