Maintenance And Servicing The Fireplace; Disposal Of Ashes; Chimney Inspection/Cleaning; Firebox Refractory - Heat & Glo LifeStyle RH-36 Series Owner's Manual

Woodburning
Table of Contents

Advertisement

11 11

Maintenance and Servicing the Fireplace

A. Disposal of Ashes
Ashes should be placed in a metal container with a tight-fi t-
ting lid. The closed container of ashes should be placed on
a noncombustible fl oor or on the ground, well away from all
combustible materials, pending fi nal disposal. If the ashes
are disposed of by burial in soil or otherwise locally dis-
persed, they should be retained in the closed container until
all embers have thoroughly cooled.
WARNING
Fire Risk

Disposal of ashes

Ashes should be placed in metal container with tight
fi tting lid.
Do not place metal container on combustible
surface.
Ashes should be retained in closed container until all
embers have thoroughly cooled.
WARNING
Fire Risk
Prevent creosote buildup
Inspect chimney once every two months during heating
season.
Remove creosote to reduce risk of chimney fi re.
Ignited creosote is extremely HOT.
Remove 8 screws
(9 for King), lift top
cover.
Cap Top
(Be sure
holes in
cap top
and cap
base are
aligned.)
Cap Base
European Copper Series
Termination Cap
(CT3-King shown)
Figure 11.1 Chimney & Termination Cap Cleaning
Remove screws,
lift top cover.
Top Cover
Cap
Chimney
TR344/TR342
Round
Termination Cap
Heat & Glo • RH-36/RH-42 • 4044-153 Rev S • 06/07
B. Chimney Inspection/Cleaning
Inspect the chimney internally for obstructions and construc-
tion damage. Flue pipe joints and seams must be continu-
ous and mechanically tight.
The chimney should be inspected once every two months
during the heating season.
If creosote has accumulated, it should be removed to reduce
the risk of a chimney fi re.
Refer to Figure 11.1 to remove/reinstall termination caps.
C. Firebox Refractory
Check fi rebox refractory for excessive cracks or gaps. If
cracks exceed 1/4 in. (6 mm) in width the refractory should
be replaced. See Section 12 for replacement information.
Note: As you use the fi replace, expansion and contraction
will cause minor cracking of the refractory. This is normal,
unavoidable, and will not affect the performance of the
fi replace. If the cracks become large enough that the metal
behind the refractory is exposed or large pieces fall out, the
panels should be replaced.
Remove 4 screws
and lift top pan off.
Cap
Slip
Section
ST375
Square
Termination Cap
WARNING
Fire Risk
Inspect fi replace refractory annually.
Crumbling, deteriorated refractory can allow
overheating of surrounding materials.
1. Remove the 4 screws.
2. Remove the screen.
3. Remove the baffle.
Cap
Chase
TS345/TS345P
Square
Termination Caps
Remove 2 screws from
the front and back and
lift the top off.
TCT375
Terra Cotta
Termination Cap