B. Chase Top
A metal chase top is required to seal the top of the chase
around the chimney pipe. The top should include a turn-
down and drip edge to prevent water from seeping into the
chase. Provide a 1/8 in. (3 mm) gap around the fl ue pipe
and slope the top downward away from the penetration. See
Figure 6.4.
All seams must be caulked to prevent leaks.
A chase installation must use a chase top. Chase tops
are available from your Heat & Glo dealer or may be fi eld
constructed.
Attach the chase top to the top of the chase.
Caulk
Figure 6.4
Chase Top Construction
24
Termination Cap
2 in. (51 mm) Collar
on Chase Top
Storm Collar
Slope Downward
Turn-down
Drip Edge
Chase
(Chimney)
.018 (26 ga) min.
Galvanized

Chase Top

Heat & Glo • RH-36/RH-42 • 4044-153 Rev S • 06/07