Model:
Twilight-II*
* Does not ship with interior or
exterior door, or TL-Trim kit.
These items must be
purchased separately.
Important operating and
maintenance instruc-
tions included.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing proper-
ty damage, personal injury, or death.
• Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
• What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed by
a qualified installer, service agency, or the gas
supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must
be installed in accordance with the manufacturer's instruc-
tions and the manufactured home construction and safety
standard, Title 24 CFR, Part 3280 or Standard for Installa-
tion in Mobile Homes, CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indi-
cated on the rating plate.
CAUTION
DO NOT DISCARD THIS MANUAL
Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05
Owner's Manual
Installation and Operation
Leave this manual with
party responsible for
use and operation.
WARNING
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
Glass and other surfaces are hot during
operation and cool down.
• Keep children away.
• CAREFULLY SUPERVISE children in same room as
appliance.
• Alert children and adults to hazards of high
temperatures.
• Do NOT operate with protective barriers open or
removed.
• Keep clothing, furniture, draperies and other
combustibles away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fixed glass panel. Do
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber or
gas fitter;
• a CO detector shall be installed in the room where the
appliance is installed.
Installation and service of this appliance should be
performed by qualified personnel. Hearth & Home
Technologies suggests NFI certified or factory-trained
professionals, or technicians supervised
by an NFI certified professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo LifeStyle Twilight-II

  • Page 1 Technologies suggests NFI certified or factory-trained professionals, or technicians supervised This appliance is only for use with the type(s) of gas indi- by an NFI certified professional. cated on the rating plate. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 2 IN CANADA Serial Number Model: XXXXXXXX ALTITUDE: 0-0000 FT. 0000-0000FT. (Modele): MAX. INPUT BTUH: 00,000 00,000 MIN. INPUT BTUH: 00,000 00,000 Serial ORIFICE SIZE: #XXXXX #XXXXX XXXXXXXX (Serie): Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 3: Table Of Contents

    C. Optional Accessories ....... 15 D. Intellifire Ignition System Wiring ....16 E. Junction Box Installation ......17 F. Wall Switch Installation for Fan ....17 = Contains updated information. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 4: Listing And Code Approvals Section

    Appliance unit was tested to the following ASTM standards and burn, whether flame proofed or not, or whether plastered at the Stork Twin City Testing laboratory. or unplastered shall be considered combustible materials. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 5: Getting Started

    Keep appliance dry. approved by Hearth & Home Technologies. • Mold or rust may cause odors. • Water may damage controls. Any such action may cause a fire hazard. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 6: Framing And Clearances A. Selecting Appliance Location

    • Clearances and Mantel Projections (Section 3.B and 3.C) GLASS FLUSH TO EXTERIOR INSULATED ENVELOPE GLASS Model Minimum Minimum Minimum Inches Twilight-II 1092.2 12.7 609.6 914.4 1092.2 Millimeters Figure 3.1 Appliance Locations Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 7: Clearances

    Non-Combustible Combustible Standoff Sides of Opening Opening Opening to Ceiling Floor Flooring Height Appliance (Height) (Depth) (Width) 41-1/4 3-3/8 Inches 1048 1118 Figure 3.3 Clearances to Combustibles Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 8: Mantel Projections

    Figure 3.4 Indoor Clearances to Mantels or other Figure 3.5 Indoor clearances to Mantel Legs or Wall Combustibles above Appliance Projections (Acceptable on both sides of opening.) Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 9: Termination Locations

    1 foot below the termination. the appliance will maximize comfort and cleanliness. Figure 4.1 Minimum Clearances for Appliance Opening Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 10: Appliance Preparation

    NOTE: Caulk behind all flanges before securing to the exterior. Figure 5.2 Proper Positioning, Leveling and Securing of a Appliance CAUTION Do NOT notch into the framing around the appliance spacers. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 11 (12 inches above and on both sides of the exterior face of the appliance). Use hightemp caulk to seal between combustible sheathing housewrap and non- combustible sheathing. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 12: Gas Information

    Minimum 5.0 inches 11.0 inches Inlet Pressure w.c. w.c. Maximum Inlet 14.0 inches 14.0 inches Gas Pressure w.c. w.c. Manifold 3.5 inches 10.0 inches Pressure w.c. w.c. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 13 Do NOT change the valve settings. • This valve has been preset at the factory. • Changing valve settings may result in fire hazard or bodily injury. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 14: Electrical Information

    • Low voltage and 110 VAC voltage cannot be shared within the same wall box. NOTE: Waterproof insulated wire should be used when wiring the junction box. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 15: Optional Accessories

    NOTE: If any of the original wire as supplied with the appliance must be replaced, it must be replaced with the type 105 C rated wire. Figure 7.1 Fan Wiring Diagram Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 16: Intellifire Ignition System Wiring

    NOTE: 1. Ignition module, valve, pilot, and wall switch operate on 3 volts. Uninterrupted 120 VAC is required at junction box unless equipped with battery back-up. Figure 7.3 Intellifire Pilot Ignition (IPI) Wiring Diagram Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 17: Junction Box Installation

    WALL SWITCH Figure 7.5 Junction Box Wired to Wall Switch box, and connect to the top fan switch connector (1/4 inch male) as shown. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 18: Finishing

    Combustibles above Appliance TOP VIEW MEASURED FROM CORNER ½ IN. FIREPLACE HOOD Figure 8.2 Clearances to Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening.) Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 19 (see Figure 8.3). • Seal joints between the finished wall and appliance top and sides using only a 300 F minimum sealant. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 20 FACING MATERIAL 6 INCH MAXIMUM PROJECTION FROM SURFACE OF FIREPLACE APPLIANCE HOOD NON-COMBUSTIBLE BRICK LEDGE MUST BE TIGHT TO APPLIANCE FACE OR NON-COMBUSTIBLE SHEATHING Figure 8.5 Exterior View Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 21: Appliance Setup

    Placement of Ember Materials • Save the remaining ember materials for use during appli- ance servicing. The embers provided should be enough for 3 to 5 applications. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 22: Positioning The Logs

    LOG #2 (SRV2005-700): Position log #2 on the left grate bar and the pilot assembly. Use the cut out notches on the log to position it as shown. 2005-937D Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 23 STEP 6. LOG #5 (SRV2005-704): Using the sharp notch on the heavy end of log #5, align it on the grate tine and on log #4 as shown. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 24: Glass Assembly

    Removing Glass Assembly Remove wing nuts and glass clips around glass door. Re- move glass door from the appliance. Replacing Glass Assembly Replace the glass door on the appliance. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 25: Operating Instructions

    • Only use glass door certified for use with appliance. and any gas control which has been under water. • Glass replacement should be done by qualified technician. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 26: Lighting Appliance

    For additional information on operating your Hearth & Home Technologies fireplace, please refer to www.fireplaces.com. Final Inspection by 593-913D _________________________________ Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 27: After Appliance Is Lit

    In an Intellifire ignition system it is normal to see the pilot flame, but it should turn off burn continually? when ON/OFF is turned off. In a standing pilot system the pilot will always stay on. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 28: Troubleshooting

    The sensor rod may be contaminated. Clean sensor rod with emery cloth. c. Module is not Verify that module is securely grounded to metal chassis of appliance. Verify grounded. that wire harness is firmly connected to module. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 29 Verify that spark gap from ignitor to pilot hood is .17 in. or 1/8 in. large. c. Module is not Verify module is securely grounded to metal chassis of appliance. grounded. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 30: Maintaining And Servicing Appliance

    • Restricted air flow affects burner operation. control compartment • Burner, burner ports Risk of: • Fire • Delayed ignition or explosion • Exposure to combustion fumes • Odors Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 31 2. Replace batteries in remote transmitters and battery-powered receivers. 3. Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure or leaking. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 32: Reference Materials

    Inches Millimeter Location Inches Millimeter 4-3/4 36-1/4 41-7/8 1062 21-1/2 1091 40-3/4 1036 42-1/8 1070 40-3/4 1035 23-1/2 3-3/8 35-5/8 2-1/2 4-1/2 Figure 13. 1 Appliance Dimensions Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 33: Service Parts

    Twilight-II B. Service Parts Beginning Manufacturing Date: 6-05 (NG, LP) Exploded Parts Diagram Ending Manufacturing Date: ___ Log Set Assembly Part number list on following page. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 34 NGK-TWI Conversion Kit LP LPK-TWI Wall Switch Kit, Off-white WSK-21-HTI Wall Switch Kit, White WSK-21-W-HTI Fan Kit GFK-160T See following page for additional IPI service part numbers. Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 35: Service Parts

    2087-109 Valve Bracket 2087-116 Orifice Bracket Gasket 2087-110 Valve Plate Gasket 2087-112 Battery Pack 593-594A 3V Adaptor 593-593A Spud LP 593-527 Spud NG 593-528 Pilot Tube 446-301 Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 36: Warranty

    3. HEAT & GLO reserves the right to make changes at any time, without notice, in design, material, specifications and prices of the Product. HEAT & GLO also reserves the right to discontinue styles and products. © 2005 Hearth & Home Technologies Inc. 060-981D 3/05 Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...
  • Page 37: Contact Information

    6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Printed in U.S.A. - Copyright 2005 Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05...