Electrical Information; Recommendation For Wire; Connecting To The Appliance; Intellifi Re Ignition System Wiring - Heat & Glo LifeStyle Dakota 42 Owner's Manual

Table of Contents

Advertisement

7

Electrical Information

A. Recommendation for Wire
Note: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA
70-latest edition or the Canadian Electric Code,
CSA C22.1.
B. Connecting to the Appliance
WARNING
Shock Risk
Explosion Risk
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch
Incorrect wiring will damage millivolt
values.
Incorrect wiring will override IPI safety
lockout and may cause explosion.
This appliance may be used with a wall switch.
Use low resistance thermostat wire for wiring from ignition
system to the wall switch.
Keep wire lengths short as possible by removing any
excess wire length, not to exceed 18 ft.
Low voltage and 110 VAC voltage cannot be shared within
the same wall box.
ON/OFF
WALL
SWITCH
IGNITION
MODULE
(3V)
VALVE
Figure 7.1
Intellefi re Pilot Ignition (IPI) Wiring Diagram
Heat-N-Glo Lifestyle Collection • Dakota 42/Dakota 42H • 4036-905 Rev I • 10/05
IGNITION MODULE
BATTERY
PACK
FLAME SPARKER/
SENSOR
BATTERY
PACK
LOW VOLTAGE
SEE NOTE 1
C. Intellifi re Ignition System Wiring
This appliance requires two "D" size batteries (3V) supply
to the appliance valve for operation. A wiring diagram is
shown in Figure 7.1.
This appliance is equipped with an Intellifi re control valve
which operates on a 3 volt system.
This appliance is supplied with a battery pack which is
located inth e ON/OFF switch terminal box.
The battery pack requires two D cell batteries (not
included).
Battery polarity must be correct or module damage will
occur.
Shock Risk
Replace damaged wire with type 105° C
rated wire.
Wire must have high temperature
insulation.
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
I
3 VAC
S
WHT
ORG
GROUND TO
FIREPLACE
CHASSIS
RED
PIGGYBACK
ON/OFF SWITCH
CAUTION
CAUTION
CAUTION
INTERMITTENT
PILOT
IGNITOR
VALVE
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dakota 42h

Table of Contents