4.5 Default Auto Exposure Level Adjustment
4.5
Default Auto Exposure Level Adjustment
The density level for the Default Auto Exposure Level Adjustment can be
set to one of nine settings. With copy density 5 as the middle setting,
decreasing the setting value lightens the density and increasing the
setting value darkens the density.
Use the main switch to turn off
1
the copier. While holding down
the Exposure Control Key 5,
turn on the copier.
Press the Exposure Control Key
2
5 again. The copier enters the
Default Auto Exposure Level
Adjustment.
EP1030/EP1030F
Copy density 1 (lightest)
Copy density 2 (lighter)
Copy density 3 (lighter)
Copy density 4 (lighter)
Copy density 5 - middle setting
Copy density 6 (darker)
Copy density 7 (darker)
Copy density 8 (darker)
Copy density 9 (darkest)
36
Rev. 1.x/22.05.02