Removing A Hot-Plug Power Supply Unit; Preliminary Steps - Fujitsu PRIMERGY TX140 S2 Upgrade And Maintenance Manual

Primergy
Hide thumbs Also See for PRIMERGY TX140 S2:
Table of Contents

Advertisement

6.3.2

Removing a hot-plug power supply unit

Customer Replaceable Unit
(CRU)
Tools: tool-less
I
Note for servers using CMA (Cable Management Arm)
Regarding of removing power supply units, additional tasks are needed,
due to an interference between CMA stopper and the power supply units.
Ê Unlock the CMA stopper.
Ê Remove the CMA stopper with the mounted crossbar.
Ê Support the CMA stopper, the crossbar and the CMA including cables
with your right hand.
Ê Remove the power supply unit and install a dummy cover into the
empty bay.
Ê Remount the complete assembly (CMA stopper, crossbar and CMA)
into the rail.
6.3.2.1

Preliminary steps

No steps needed.
TX140 S2
Upgrade and Maintenance Manual
Power supply
Hardware: 5 minutes
109

Advertisement

Table of Contents
loading

Table of Contents