■ ACC set mode
Selects the desired band for the operating frequency
band control signal output from [ACC2–A] (pin 4).
Selects the desired band for the operating frequency
band control signal output from [ACC2–B] (pin 4).
Selects the switching relay type for [RELAY] from
Lead and MOS-FET.
Select the suitable relay type when connecting a non-
Icom linear amplifier.
Selects the desired item for an external meter indica-
tion (main readout).
(continued)
• MAIN : Outputs the band signal displayed in main
readout.
• SUB : Outputs the band signal displayed in sub
readout.
• TX
: Outputs the band signal, that can be trans-
mitted. (default)
• MAIN : Outputs the band signal displayed in main
readout.
• SUB : Outputs the band signal displayed in sub
readout.
• TX
: Outputs the band signal, that can be trans-
mitted. (default)
• Lead
: Use mechanical relay.
(16 V DC/0.5 A max.; default)
• MOS-FET : Use semiconductor type relay. (250
V/200 mA max.)
• Auto
: Outputs the receiving signal strength
level during receive, and outputs the se-
lected level (selected with [METER]), dur-
ing transmit. (default)
• S(MAIN) : Outputs the receiving signal strength level
during receive.
• Po
: Outputs the transmitting power level dur-
ing transmit.
• SWR
: Outputs the VSWR level during transmit.
• ALC
: Outputs the ALC level during transmit.
• COMP : Outputs the compression level during
transmit.
• V
d
: Outputs the drain terminal voltage of the
final amplifier MOS-FETs.
• I
d
: Outputs the drain current of the final am-
plifier MOS-FETs.