Server Shutdown Command - HP NetServer AA 4000 Administrator's Manual

Hp netserver aa 6200 solution release 3.0 administrator’s guide
Hide thumbs Also See for NetServer AA 4000:
Table of Contents

Advertisement

Chapter 5

Server Shutdown Command

This command shuts down the CE's operating system and then shuts down the operating system
on each available IOP.
Note:
This command is the preferred method for shutting down the server.
Command
Server Shutdown Operation From IOPx
Console Syntax MTCCONS Server Shutdown Operation From IOPx
x – the ID number of the IOP (1 or 2)
Variables
The monitor on the specified IOP initiates a shutdown of the server. First, a
Results
request is issued by the monitor on the specified IOP to the CE Endurance
Manager service to shut down the operating system if the CE operating
system is booted. The CE Endurance Manager service initiates the CE
operating system shutdown. When complete, the monitor on the specified
IOP initiates a shutdown of the remote IOP (if it is available), followed by a
shutdown of the local IOP. The server reboots when the IOPs and CEs
become available.
If the system fails to shut down, perform the following steps:
See Also
CE Disable Auto Boot
CE Disable Auto Synch
CE_O/S Shutdown Command
IOP Shutdown Operation
IOPn.Monitor Enable Auto Start
Tuple Shutdown Operation
160
Check the status of the server in the Endurance Manager Main window
on the IOPs and the CEs. Determine which, if any, system elements were
removed.
Review the Windows NT Event Viewer for a message that indicates that
the command failed.
Shut down the server using the procedures in
Commands
Chapter
9.