en | Installation
4

Installation

Perform the following steps to install the B450.
Notice!
Remove all power (AC and Battery) before making any connections. Failure to do so may
result in personal injury and/or equipment damage.
4.1

Setting the bus address

The B450 Conettix Plug-in Communicator Interface address switch provides the value for the
module's address. The figure below shows the address switch setting for address 1. Refer to
the table below for panel-specific settings.
Figure 4.1: Address switch set to address 1
Control panels
USB or SMS configuration
setting
B5512/B4512/
B3512,D9412GV4/
D7412GV4/D7212GV4
D9412GV4/D7412GV4/
D7212GV4
D9412GV4/D7412GV4/
D7212GV4, D9412GV3/
D7412GV3/D7212GV3
D9412GV4/D7412GV4/
D7212GV4, D9412GV3/
D7412GV3/D7212GV3
For D9412GV4/D7412GV4/D7212GV4 configurations, SDI2 bus connection is the recommended configuration
1
option, but SDI bus configuration is also supported.
Table 4.1: B450 address switch settings
4.2
Insert the B44x communication module (required and available
separately)
Insert the desired B44x communication module into the slot of the B450 until you feel the
module "click" into place.
2013.09 | 02 | F.01U.282.875
Switch
Control panel
position
bus address
0
N/A
1
1
2
2
4
88
5
92
Installation and Operation Guide
Bus type
Function
Any
Change configuration
SDI2
Automation, RPS, or Reporting
SDI2
Automation, RPS, or Reporting
SDI
RPS or Reporting
1
SDI
RPS or Reporting
1
Conettix Plug-in Communicator
Interface