44
en | Specifictions and certifications
7

Specifictions and certifications

7.1

Technical specification

Environmental considerations
Relative humidity
Temperature (operating)
Properties
Dimensions (HxWxD)
Power requirements
Current
Voltage
Wiring
Data bus wire gauge
Data bus wire length
USB cable
Compatible enclosures
B10 ᅳ 35.6 cm x 31.8 cm x 7.6 cm (14 in x 12.5 in x 3 in)
B11 ᅳ 27.8 cm x 25.9 cm x 8.32 cm (10.9 in x 10.2 in x 3.3 in)
D8103 ᅳ 41 cm x 41 cm x 9 cm (16 in x 16 in x 3.5 in)
D203 ᅳ 19.68 cm x 13.05 cm x 6.35 cm (7.75 in x 5.14 in x 2.50 in)
Notice!
Temporary loss of communication may be caused by static when using anyone of the above
enclosures.
2013.09 | 02 | F.01U.282.875
Up to 93% non-condensing
0゚ - +49゚C (+32゚ - 120゚F)
79 mm x 128 mm x 38 mm (3.11 in x 5.03 in x 1.50 in)
Standby: B450 with B440/B441 = 60 mA
Alarm: B450 with B440/B441 = 180 mA
(B450 bus operation): 12 VDC nominal
12 AWG to 22 AWG
Maximum distance – Wire size :
22 AWG (0.65 mm) --> 12 m (40 ft)
18 AWG (1.0 mm) --> 30 m (100 ft)
16 AWG (1.3 mm) --> 48 m (158 ft)
12 AWG (2.0 mm) --> 122 m (400 ft)
Using a separate UL listed power supply, such as the B520
Auxiliary Power Supply Module, connected to the B450 within
the specification listed above, the wire distance can be
extended up to 300 m (1000 ft)
Type A male-to-male
Installation and Operation Guide
Conettix Plug-in Communicator
Interface
Bosch Security Systems, Inc.