16
en | Installation
4.5.3
Wire to an option bus control panel
Run the wiring connections from the module to the data bus terminals on the compatible
control panel.
Notice!
When wiring the connections between the option bus terminal strip and the B450, verify the
terminal position of the colored wires as they may be in a different orientation (option bus =
R, B, G, and Y) and (B450 = R, Y, G, and B).
Figure 4.7: Wiring to an option bus terminal strip
Callout ᅳ Description
1 ᅳ Compatible control panel (FPD-7024 control panel shown)
2 ᅳ B450
3 ᅳ Terminal strip wiring
For complete wiring instructions, refer to the control panel documentation.
2013.09 | 02 | F.01U.282.875
2
1
R
B
G
Y
Installation and Operation Guide
R
R
Y
Y
G
G
B
B
3
Conettix Plug-in Communicator
Interface
Bosch Security Systems, Inc.