2.5

Disable Factory Defaults

Program the Disable Factory Defaults feature in
Location 900.
The default value is 0.
This feature disables the DEFAULT button on the
control panel printed circuit board (PCB) to prevent
an operator from resetting the control panel to default
values. This feature also prevents using a
programming key when the system is disarmed.
Program 0 into this location to enable the DEFAULT
button and to allow updates to location data using the
programming key. Program 15 to disable the
DEFAULT button and to require the Installer Code
to program the control panel.
If the Installer Code is unknown, you must return the
control panel to your Bosch Distributor for exchange.
A nominal fee applies for this service.
Using this feature is not recommended.
If you need to disable the DEFAULT button, holding
down the DEFAULT button on the PCB when
programming this location prevents you from
accidentally setting this option.
To prevent manual resetting of the control panel
to default values:
1. Enter the Installer Code (the default is 1234) and
press [#] to enter Installer's Programming Mode.
Two beeps sound and the remote codepad shows
the data programmed in Location 000.
If you are using the remote codepad, the STAY
and AWAY indicators flash to indicate you
entered Installer's Programming Mode.
2. Enter [9 0 0 #] to move to Location 900.
3. Press and hold the DEFAULT button.
The DEFAULT button is located at the top of the
PCB next to the PROGRAMMING KEY socket.
4. Enter [1 5 *] to program 15 into Location 900.
5. Release the button.
6. Enter [9 6 0 #] to exit from the Installer's
Programming Mode.
Two beeps sound and the system returns to the
disarmed state. If you are using a remote
codepad, the STAY and AWAY indicators turn
off to indicate the system is disarmed.
If Location 900 is not programmed as 15, use one of
these procedures to successfully reset the control
panel to the factory default settings.
To reset the control panel using the Installer
Code:
1. Enter the Installer Code (the default is 1234) and
press [#] to enter Installer's Programming Mode.
Bosch Security Systems, Inc. | 12/08 | F01U089401-02
ICP-CC404 | Installation Guide | 2.0
Two beeps sound. The STAY and AWAY
indicators flashes to indicate you entered
Installer's Programming Mode.
2. Enter [9 6 5 #].
Two beeps sound after the control panel is
successfully reset.
3. Enter [9 6 0 #].
Two beeps sound. The STAY and AWAY
indicators stop flashing and the system returns to
the disarmed state.
The control panel is now successfully reset to the
factory settings.
To reset the control panel using the default
button:
1. Disconnect the AC MAINS supply and the
backup battery from the control panel.
Press and hold the DEFAULT button. The
DEFAULT button is located at the top of the
PCB next to the PROGRAMMING KEY socket.
2. Reconnect the AC MAINS supply to the control
panel.
3. Wait 3 to 5 sec and release the button.
4. Enter [2 5 8 0 *] to disarm the system using the
default Master Code.
The control panel is successfully reset to the
factory settings.
If the option to restore the default control
panel settings is disabled using Location
900:
• The dialer seize relay (RL2) clicks four
times. You must return the control
panel to Bosch Security Systems, Inc.
for exchange. If the Installer Code is
unknown, a service fee is charged to
unlock the control panel's memory
• When programmed to disable the
default control panel setting, you
cannot use the command [961#] to
retrieve the programming data.
• The use of this feature is not
recommended.
Programming