Basic Pager Reporting Format; Table 36: 4+2 Express Transmission Code Descriptions - Bosch ICP-CC404 Installation Manual

Hide thumbs Also See for ICP-CC404:
Table of Contents

Advertisement

ICP-CC404 | Installation Guide | 10.0
Table 36:
4+2 Express Transmission Code
Descriptions
Code
Description
SSSS
Subscriber ID Number
A
Alarm
C
Channel Number
H
0
Zero
T
Trouble
B
Bypass
E
AC Fail Code 1
AC
AC Fail Code 2
L
Low Battery Code 1
L
Low Battery Code 2
B
O
Open
C
Close
U
User Number
R
Alarm Restore Code
TR
Trouble Restore Code
B
Bypass Restore Code
R
E
AC Fail Restore Code 1
R
AC
AC Fail Restore Code 2
R
L
Low Battery Restore Code 1
R
L
Low Battery Restore Code 2
BR
D
Duress Code 1
D
Duress Code 2
0
st
P
Panic Code 1
nd
P
Panic Code 2
CH
T
Test Code
E

10.1.4 Basic Pager Reporting Format

Although Basic Pager Format requires some
interpretation of the numbers that appear on the
display, it can differentiate between 1000 different
control panels if a number of control panels report to
the one pager.
44
Dialer Reporting Formats
st
digit
nd
digit
st
digit
nd
digit
st
digit
nd
digit
st
digit
nd
digit
st
digit
nd
digit
digit
digit
To set up Receiver 1 for basic pager reporting:
1. Program the Basic Pager's access telephone
number in Locations 000 to 015 (refer to Section
11.1 Primary Telephone Number for Receiver 1 and
Receiver 2 on page 46).
2. Program the Subscriber ID Number in Locations
034 to 039 (refer to Section 11.5 Subscriber ID
Number for Receiver 1 and Receiver 2 on page 47).
3. Select Pager Handshake (Option 5) in
Location 032 (refer to Section 11.3 Handshake Tone
for Receiver 1 and Receiver 2 on page 47).
4. Program Basic Pager Format (Option 5) in
Location 033 (refer to Section 11.4 Transmission
Format for Receiver 1 and Receiver 2 on page 47).
To set up Receiver 2 for basic pager reporting:
1. Program the Basic Pager's access telephone
number in Locations 040 to 055 (refer to Section
11.1 Primary Telephone Number for Receiver 1 and
Receiver 2 on page 46).
2. Program the Subscriber ID Number in Locations
074 to 079 (refer to Section 11.5 Subscriber ID
Number for Receiver 1 and Receiver 2 on page 47).
3. Select Pager Handshake (Option 5) in Location
072 (refer to Section 11.3 Handshake Tone for
Receiver 1 and Receiver 2 on page 47).
4. Program Basic Pager Format (Option 5) in
Location 073 (refer to Section 11.4 Transmission
Format for Receiver 1 and Receiver 2 on page 47).
The example in Figure 6 shows:
Transmission from Subscriber ID Number 5678
Zone 2 in alarm
Zone 3 manually isolated
The system is armed
The Panic Zone is normal
The AC is connected
There is no fault condition.
Bosch Security Systems, Inc. | 12/08 | F01U089401-02