If you do not want the system to send Zone Bypass
Reports, program Locations 325 and 326 to 0 (refer to
Section 15.1 Zone Status – Bypass Reports on page 60).
4 – Forced Arming Allowed
If this option is selected, the system can be armed
with the zone unsealed. If this option is not selected,
the system does not allow the User Code holder to
arm the system until the zone is sealed or manually
isolated. Refer to Section 4.11 Isolating Zones on
page 21 for more information.
8 – Zone Restore Report
If this option is selected, the zone sends Restore
Reports when the zone is restored. If this option is
not selected, the zone does not send Restore Reports
when the zone is restored.
If a non-24-Hour zone is not restored when the
system is disarmed, the system automatically sends a
Zone Restore Report for that zone. All 24-Hour zones
send a Zone Restore Report only when the zone is
restored.

14.3.7 Zone Report Code

If you want the control panel to send Zone Alarm
Reports, program this location as 1. If not, program
this location as 0.

14.3.8 Zone Dialer Options

By default, a zone reports only to Receiver 1. Table 45
lists the reporting options for the zone.
Table 45:
Zone Dialer Options
Option
Description
0
No report required
1
Receiver 1
2
Receiver 2
4
Receiver 1 and Receiver 2
8
Receiver 2 only when Receiver 1 fails
14.4

Swinger Shutdown Count for Siren

Program the Swinger Shutdown Count for Siren in
Location 323.
The default value is 3.
This location determines the number of times the
sirens can be activated before lockout options take
effect. Programming a 0 sets the count to unlimited.
This location has no effect unless you program at
least one zone for lockout siren. Refer to Section 14.3.4
Zone Options 1 on page 57 to program zones for
lockout siren.
Only alarms activated from zone inputs can decrease
the Swinger Shutdown Counter. Alarms such as
Codepad Panic, Access Denied, and other system
alarms do not affect the Swinger Shutdown Count.
Bosch Security Systems, Inc. | 12/08 | F01U089401-02
ICP-CC404 | Installation Guide | 14.0 Zone Information
When the sirens are operating, its counter is only
decreased by the first zone that activated the alarm.
Any other zones that are activated during Siren Run
Time do not affect the counter.
When the Swinger Shutdown Count is reached, all
zones that were activated are locked out according to
their individual lockout settings.
Example
All eight zones are programmed for lockout siren
with a Swinger Shutdown Count of 3. If Zone 1
activates an alarm, the Swinger Shutdown Count is
decreased by one after the end of Siren Run Time to
a swinger shutdown count of 2.
After the Siren Run Time is reset from the previous
alarm, Zone 2 activates an alarm and activates the
sirens. After the sirens reset, the swinger shutdown
count is decreased again to 1.
If Zone 3 also activates an alarm after the sirens are
reset from Zone 2, the Swinger Shutdown Count is
decreased to 0, which locks out all three zones from
sounding the sirens until the system resets.
At this point, the Swinger Shutdown Count for Sirens
resets to 3 and the process of swinger shutdown for
remaining zones begins again until all zones are
locked out.
14.5

Swinger Shutdown Count for Dialer

Program the Swinger Shutdown Count for Dialer in
Location 324.
The default value is 6.
This location determines the number of times the
dialer can be activated before lockout options take
effect. This location has no effect unless you program
at least one zone for lockout dialer. Refer to Section
14.3.4 Zone Options 1 on page 57 to program zones for
lockout dialer.
Only alarms activated from zone inputs can decrease
the Swinger Shutdown Counter. Alarms such as
Codepad Panic, Code Retries, and other system
alarms do not affect the Swinger Shutdown Count.
When the dialer is online, its counter is only
decreased by the first zone that activated the alarm.
Any other zones that are activated while the dialer is
online do not affect the counter.
When the Swinger Shutdown Count is reached, all
zones that were activated are locked out according to
their individual lockout settings.
If Lockout Dialer is enabled for any zone,
the last restore signal is not sent until the
system is disarmed.
59