Command 999 - Display The Panel Type Or Software Version Number; Table 6: Command 965 Defaults; Table 7: Control Panel Type - Bosch ICP-CC404 Installation Manual

Hide thumbs Also See for ICP-CC404:
Table of Contents

Advertisement

ICP-CC404 | Installation Guide | 2.0
Table 6:
Command 965 Defaults
Location
Description
032
Handshake Tone for Receiver 1
033
Transmission Format
034 to 039
Subscriber ID Number
332
Zone Status Reporting Options
333 and 334
Open/Close Reports
335
Open/Close Reporting Options
356 to 358
System Status – Access Denied
359
System Status Reporting Options
360 to 366
Test Report Time
367
Test Reporting Dialer Options
Example (Auto Step Mode Enabled)
To enter the Primary Telephone Number 02 (pause)
9672 1055 when Auto Step Mode is enabled:
1. Press [0 #].
You are positioned at Location 000 (the Primary
Telephone Number for Receiver 1).
2. To program the number, press:
[10 * 2 * 13 * 9 * 6 * 7 * 2 * 1 * 10 * 5 * 5 * 0*]
Example (Auto Step Mode Disabled)
To enter the Primary Telephone Number 02 (pause)
9672 1055 when Auto Step Mode is disabled:
1. Press [0 #].
You are positioned at Location 000 (the Primary
Telephone Number for Receiver 1).
2. To program the number, press:
[10 * # 2 * # 13 * # 9 * # 6 * # 7 * # 2 * # 1 * #
10 * # 5 * # 5 * # 0 *]
2.4.10 Command 999 – Display the Panel Type or
Software Version Number
When using the remote codepad, this command
shows the version of the control panel. Because
different control panels use the same printed circuit
board (PCB), it is difficult to determine the control
panel the PCB is set to.
14
Programming
Default Value
1
4
0, 0, 0, 0, 0, 1
2
11, 12
2
6, 7, 12
2
0, 0, 0, 0, 7, 1, 0
1
To show the control panel type or software
version number:
1. Enter the Installer Code (the default is 1234) and
press [#] to enter Installer's Programming Mode.
Two beeps sound and the remote codepad shows
the data programmed in Location 000.
If you are using the remote codepad, the STAY
and AWAY indicators flash to indicate you
entered Installer's Programming Mode.
2. Enter [9 9 9 #].
Two beeps sound.
If you are using the remote codepad, the codepad
displays a zone indicator corresponding to the
control panel type. Refer to Table 7 for more
information.
Table 7:
Indicator
4
8
3. Press [#] to exit from this command and return to
the Installer's Programming Mode.
4. Enter [9 6 0 #] to exit from the Installer's
Programming Mode.
Two sound and the system returns to the
disarmed state.
If you are using the remote codepad, the STAY
and AWAY indicators turn off to indicate the
system is disarmed.
Bosch Security Systems, Inc. | 12/08 | F01U089401-02
Setting
(Handshake Tone)
(Domestic)
(1 Beep)
(Receiver 2 only)
(Open/Close Reports)
(Receiver 2 only)
(Access Denied)
(Receiver 2 only)
(Test Reports)
(Receiver 1 only)
Control Panel Type
Control Panel Type
ICP-CC404
ICP-CC408
ICP-CC488

Hide quick links: