Panasonic VB-9411ADSUK Operation Instructions Manual page 81

Table of Contents

Advertisement

WARNING
Always unplug the AC plug
from the outlet and power off
the switch (STD BY) of the
CCU when mounting the Call
Logging I/F card.
RS-232C Cable
or
To Start to Print or Display Information
q Press ON/OFF key.
w Press # 9 3 .
CN5
w
Call Logging I/F
Card-A board
q
A
B
C
Serial
Printer
RS-232C to RS-232C
Call Logging RS-232C
Circuit
Signal
type(EIA)
name
AA
FG
Personal
BA
TXD
Computer
BB
RXD
CB
CTS
CC
DSR
AB
SG
CF
DCD
CD
DTR
If Connecting direct RS-232C to 9Pin (DB9) Interface
RS-232C
2
3
4
5
6
7
8
20
22
Call Logging I/F
Note : Dotted lines need not be connected when wiring.
I-21
CONNECTION OF OPTIONAL UNITS
EMI Filter
t
r
e
1
13
14
25
Printer or Personal Computer RS-232C
Signal
Pin No. and connection
name
1
1
FG
2
2
TXD
3
3
RXD
5
5
CTS
6
6
DSR
7
7
SG
8
8
DCD
20
20
DTR
DB 9
2
3
7
4
5
1
6
8
9
Personal
Computer
Call Logging
I/F Card-B board
CCU
Circuit type
EIA CCITT
AA
101
BA
103
BB
104
CB
105
CC
106
AB
102
CF
109
CD
108.2
Recevive Data
Transmit Data
Request To Send
Data Terminal Ready
Signal Ground
Carrier Detect
Data Set Ready
Clear To Send
Ring Indicator

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents