PROGRAMMING (MODE 10)
4003#-(1 to 9)
PAUSE TIMER (NCC3)
It is possible to insert a pause after the NCC3 access
code, to wait for a dial tone from the NCC3 switch.
1#: 1 second
2#: 2 seconds
3#: 3 seconds
4#: 4 seconds
5#: 5 seconds
4004#-(1 to 9)
PAUSE TIMER (NCC4)
It is possible to insert a pause after the NCC4 access
code, to wait for a dial tone from the NCC4 switch.
1#: 1 second
2#: 2 seconds
3#: 3 seconds
4#: 4 seconds
5#: 5 seconds
401n#-(0 or 1)#
(n=1-4: correspond to NCC1-4)
AUTOMATIC MF SIGNAL CONVERSION
This specify whether the MF signal conversion for
dialling out to NCC. It is useful when the system is
routed to the system X local exchanger by Lookup table
which does not accept MF signal when "132" is sent out
in Dial Pulse.
0#: No convert
1#: Convert
5000#-(4 digits password)#
PASSWORD TO ACCESS MODE 10
It is possible to set a new password to allow access to
mode 10 programming.
NOTE : Since the current password is not displayed if you
forget your password, a complete system reset
and reprogramming must be performed.
0000
0001-9999
6#: 6 seconds
7#: 7 seconds
8#: 8 seconds
9#: 9 seconds
6#: 6 seconds
7#: 7 seconds
8#: 8 seconds
9#: 9 seconds
(4 digits
passeord:
0000-9999)