CLI commands

dot1x reauth period

Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
dot1x reauth period (15m | 30m | 1h | 2h | 4h | 8h | 12h)
Sets the 802.1X reauthentication interval. Client stations must reauthenticate when this interval
expires.

dot1x reauth terminate

Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
dot1x reauth terminate
Enable this option to allow client stations to remain connected during re-authentication. Client
traffic is blocked only when re-authentication fails.
no dot1x reauth terminate
Disabled this option to block client traffic during re-authentication and only activate traffic again
if authentication succeeds.

dot1x supplicant timeout

Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
802.1x supplicant time-out <seconds>
Sets the 802.1X supplicant time-out.
Parameters
time-out in seconds.
<seconds>

inherit 8021x

Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
inherit 802.1x
Inherit 802.1x settings from parent.
no inherit 802.1x
Do not inherit 802.1x settings from parent.

bridge protocol ieee

Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
bridge protocol ieee
Enable the bridge spanning tree protocol to prevent undesirable loops from occurring in the
network that may result in decreased throughput.
no bridge protocol ieee
Disable the bridge spanning tree protocol.