NEVER attempt to clear a clogged drain valve from the front of the valve! Hot oil will
rush out creating the potential for severe burns.
DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage
to the ball inside will result in leaks and will void the Frymaster warranty.
6. After the oil has drained from the frypot,
rotate the filter handle towards the "I" to
start the pump and begin the filtering
process. There may be a slight delay
before the pump activates (see Figure
11).
7. The filter pump draws the oil through the filter medium and circulates it back up to and through
the frypot during a 5-minute process called polishing. Polishing cleans the oil by trapping solid
particles in the filter medium.
8. After the oil is filtered (about 5 minutes), close the drain valve and allow the fryer to refill. Let
the filter pump run 10 to 12 seconds after the oil begins to bubble. Turn the filter off.
The computer displays FILTER DONE alternating with YES NO.
9. Press the
(1) button when filtration is finished (see Figure 12).
The computer displays OFF.
The filter pump is equipped with a manual reset switch in case the filter motor
overheats or an electrical fault occurs. If this switch trips, turn off power to the filter
system and allow the pump motor to cool 20 minutes before attempting to reset the
switch (see photo below).
DANGER
DANGER
Pull filter handle
forward to activate
pump.
WARNING
Filter Pump Reset Switch
5-6