Avaya P333T User Manual page 129

Stackable switch software version 3.12
Hide thumbs Also See for P333T:
Table of Contents

Advertisement

Field
receive
send
all
proprietary
module/
port
Output Example:
P330-1(super)# set port flowcontrol all 2/20 on
Port 2/20 flow control administration status set to on
Avaya P333T User's Guide
Description
Controls the receipt of IEEE802.3x flow-control frames on Gigabit
ports only:
• ON indicates that the local port will act upon flow control
frames received from the far end.
• OFF indicates that the local port will discard flow control
frames received from the far end.
Controls the sending of IEEE802.3x flow-control frames from
Gigabit ports only:
• ON indicates that the local port is allowed to send flow control
frames to the far end.
• OFF indicates that the local port is not allowed to send flow
control frames to the far end.
Controls the sending and receipt of flow-control frames for any
type of ports:
• ON indicates that the local port will both act upon and send
IEEE802.3x flow control frames.
• OFF indicates that the local port will both discard and not send
flow control frames (of any type).
• PROPRIETARY indicates that the local port will both act upon
and send Avaya proprietary flow control frames.
A proprietary flow control which may be used when a P330 is
connected to M770 10/100 ports or P110 ports.
Switch number/port number
Chapter 6
CLI – Layer 2
113

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents