VClink Codec Master Control System
Press the Data Port Setup button at the top of the control page which page-flips
3.
to the Data Port Setup menu.
Select the desired Mode Modem, Data, or T120.
4.
Select the communication speed matching your equipment's serial port.
5.
Select the parity matching your equipment.
6.
Select the data bits matching your equipment.
7.
Select stop bits matching your equipment.
8.
Press the Finished button at the top of the control screen.
9.
Select a password option which returns you to the Utility/Setup page.
10.
Press the Exit button which returns you to the Conference page.