Fixture Id (R) Base + 3; Digital Input (R) Base + 4; Dac1 Output Msb (W) Base + 8; Dac1 Output Lsb (W) Base + 9 - Agilent Technologies E6198B User Manual

Functional test system switch/load unit
Table of Contents

Advertisement

B
Register Definitions

Fixture ID (R) Base + 3

Digital Input (R) Base + 4

DAC1 Output MSB (W) Base + 8

N O T E

DAC1 Output LSB (W) Base + 9

B-6
h
The Fixture ID register contains the frame address setting of the
Frame Select Jumper (JP4). When using multiple Switch/Load
Units in your test system, Jumper JP4 provides a unique
address (0-7) for each Switch/Load Unit. Factory default (one
Switch/Load Unit) is 0.
Bits
Read
Fixture ID
• Default State = 255
• Read Only
h
Digital Input is a direct read-back of the logic state present on
lines Spare_DigIn[0]- Spare_DigIn[7] of the system resource
access connector J104.
Bits
7
6
Read
Din
Din
7
6
Writing to the DAC1 Output register sets the Most Significant
Bit (MSB) of the DAC1 digital input.
To set the value of the DAC output, always write the MSB first, followed
by the LSB (register offset 9
the LSB is written. See
Bits
7
6
5
Write
x
x
DAC1
h
Writing to the DAC1 Output register sets the Least Significant
Bit (LSB) of the DAC1 digital input.
7-0
h
5
4
3
Din
Din
Din
Din
5
4
3
h
). The output of the DAC will not update until
h
"DAC
Scaling".
4
3
DAC1
DAC1
13
12
11
E6198B Switch/Load Unit User Manual
2
1
0
Din
Din
2
1
0
2
1
0
DAC1
DAC1
DAC
10
9
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts-5000

Table of Contents