Figure 5-11 Agilent E6175A Load Examples - Agilent Technologies E6198B User Manual

Functional test system switch/load unit
Table of Contents

Advertisement

5
Using Load Cards and Loads

Figure 5-11 Agilent E6175A Load Examples

UUT
Loads
P2
Load
Switches
Loading
Example
NPN Pull-up
Example #1
Multiple
Solder-In
Loads
Jumpers
Example #4
+V
CC
PNP Pull-down
Example #3
Bridge Load
Example #4
J1 even # rows
5-18
shown by J6-1, J6-2, J7-3 and J7-4. Both the power source and
return are assumed to be switched through another load card to
the UUT.
*1 are connected together
*2 are also connected together
Sheet
Metal
ISense- *1
Mounted
Loads
Load
R
S
Load
J6-1
Flyback Protection
ISense- *1
Load
R
S
Load
J6-2
Flyback Protection
ISense- *1
Load
R
S
Load
J7-3
Flyback Protection
ISense- *1
Load
R
S
Load
J7-4
Flyback Protection
J1 odd # rows
Mother Board
Interface
ISense+ *2
Relay Timer
Relay Slot
Decode Logic
NO
PwrSw1
NC
ISense+ *2
PwrSw2
NO
NC
J3
J4
ISense+ *2
NO
PwrSw3
NC
ISense+ *2
NO
PwrSw4
NC
E6198B Switch/Load Unit User Manual
Configuration
J2
Connector
Current Sense
Control
Address
Data
Power
+5, ±12V
P1
NO
PS #1
PB1
PB2
PS #2
PB3
PB4
PS #3
J5
NC
GPIB