Load Wiring; Figure 5-14 Agilent E6175A Load Wiring Schematic And P1 Pinouts - Agilent Technologies E6198B User Manual

Functional test system switch/load unit
Table of Contents

Advertisement

Load Wiring

C A U T I O N

Figure 5-14 Agilent E6175A Load Wiring Schematic and P1 Pinouts

Even # Rows
J1
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Channel 7
Channel 8
E6198B Switch/Load Unit User Manual
Figure 5-14
showing how loads are connected to P1. Load 1 connects to
Channel 1 (P1 row 16) and Power 1 (P1 row 15); Load 2
connects to Channel 2 (P1 row 14) and Power 2 (P1 row 13), and
so on.
To prevent premature pin failure from excessive current flow, when
connecting high-current (>3 amp) loads to P1, wire across all three
pins in each row (see
Odd # Rows
P1
P1
16 A
15 A
16 C
15 C
Load 1
16 E
15 E
14 A
13 A
13 C
14 C
Load 2
14 E
13 E
12 A
11 A
12 C
11 C
Load 3
12 E
11 E
10 A
9 A
9 C
10 C
Load 4
10 E
9 E
8 A
7 A
8 C
7 C
Load 5
8 E
7 E
6 A
5 A
5 C
6 C
Load 6
6 E
5 E
4 A
3 A
4 C
3 C
Load 7
4 E
3 E
2 A
1 A
1 C
2 C
Load 8
2 E
1 E
is a simplified schematic and P1 connector pinout
Figure 5-15
J1
Power 1
Power 2
Power 3
Power 4
Power 5
Power 6
Power 7
Power 8
Using Load Cards and Loads
on page 22).
P1 Connector
(Wiring Terminal View)
Row 16
Channel 1
Row 15
Power 1
Row 14
Channel 2
Row 13
Power 2
Row 12
Channel 3
Row 11
Power 3
Row 10
Channel 4
Row 9
Power 4
Row 8
Channel 5
Row 7
Power 5
Row 6
Channel 6
Row 5
Power 6
Row 4
Channel 7
Row 3
Power 7
Row 2
Channel 8
Row 1
Power 8
C
E
A
5
Load 1
Load 2
Load 3
Load 4
Load 5
Load 6
Load 7
Load 8
5-21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts-5000