System:beeper[:Immediate] [<Frequency>[,<Duration>]] - HP E8402A User And Service Manual

Vxi c-size mainframe
Table of Contents

Advertisement

SYSTem:BEEPer[:IMMediate] [< frequency >[,< duration >]]
Parameters
Comments
Error Conditions
Reset Condition
Related
Commands
128 Programming the Enhanced Monitor
SYSTem:BEEPer[:IMMediate]
parameters <frequency> and <duration> override the frequency and time settings
set by
SYSTem:BEEP:FREQ
Name
Type
< frequency > int16
125 - 6000
MIN, MAX
< duration >
float32 0.01 - 2.0
MIN, MAX
The mainframe will beep whether
Out of range values for <frequency> and <duration> do not cause the
mainframe to generate an error. Instead, the closest minimum or maximum
value is used, and the beeper sounds. For example, if you specify <frequency>
as 10000, it is clamped at 6000. Similarly, if you specify 100, it is clamped at
125.
The following table lists the most common error conditions and causes. Error
numbers and corresponding messages can be found using
Number
-221
"Settings Conflict"
*RST has no effect on the
SYSTem:BEEPer:FREQuency, SYSTem:BEEPer:TIME
causes the mainframe to beep. The optional
and
SYSTem:BEEP:TIME
Range
Default
1000
Frequency of beep, in Hertz
0.2
Duration of beep, in seconds
SYSTem:BEEP:STATe
Message
The mainframe's power is off.
SYSTem:BEEP
command.
.
Description
is ON or OFF.
query.
SYSTem:ERRor?
Probable Cause
Chapter 3