Status:questionable:voltage:level? <Supply>[,Min|Max] - HP E8402A User And Service Manual

Vxi c-size mainframe
Table of Contents

Advertisement

STATus:QUEStionable:VOLTage:LEVel? < supply >[,MIN|MAX]
Parameters
Returned Data
Comments
Reset Condition
Related
Commands
122 Programming the Enhanced Monitor
The
STATus:QUEStionable:VOLTage:LEVel?
representing the last measurement of the power supply voltage.
Name
Type
< supply >
enumerated P24, P12, P5,
optional
optional
parameter
enumerated
Type
Range
float32
The measurement returned is the last measurement made on the supply
identified with <supply>. Under normal operation, this should be within the
last 2 seconds. Voltage is not measured during a *TST? or CAL? operation, so
a query to
STAT:QUES:VOLT:LEV?
before the long operation was entered. If the power of the mainframe is off,
this query will return the last measurement made before power turned off.
The optional MIN and MAX parameter allows the power supply's voltage
limits to be queried.
warning point for the 5V supply.
*RST does not affect the status system.
STATus:QUEStionable:VOLTage:EVENt?,
STATus:QUEStionable:VOLTage:CONDition?,
STATus:QUEStionable:VOLTage:ENABle?,
STATus:QUEStionable:VOLTage:ENABle
query returns a floating number
Range
Default
none
N2, N5PT2, N12
N24, P5STby, P5EXt
MIN, MAX
none
Default
None
power-supply voltage
will return the last measurement made
STAT:QUES:VOLT:LEV? P5, MAX
Description
Indicates which power supply
current is being queried
When added after < supply >,
queries the maximum and
minimum voltage limits.
Description
will return the limit
Chapter 3