STATus:QUEStionable:VOLTage:LEVel? < supply >[,MIN|MAX]
Parameters
Returned Data
Comments
Reset Condition
Related
Commands
122 Programming the Enhanced Monitor
The
STATus:QUEStionable:VOLTage:LEVel?
representing the last measurement of the power supply voltage.
Name
Type
< supply >
enumerated P24, P12, P5,
optional
optional
parameter
enumerated
Type
Range
float32
•
The measurement returned is the last measurement made on the supply
identified with <supply>. Under normal operation, this should be within the
last 2 seconds. Voltage is not measured during a *TST? or CAL? operation, so
a query to
STAT:QUES:VOLT:LEV?
before the long operation was entered. If the power of the mainframe is off,
this query will return the last measurement made before power turned off.
•
The optional MIN and MAX parameter allows the power supply's voltage
limits to be queried.
warning point for the 5V supply.
*RST does not affect the status system.
STATus:QUEStionable:VOLTage:EVENt?,
STATus:QUEStionable:VOLTage:CONDition?,
STATus:QUEStionable:VOLTage:ENABle?,
STATus:QUEStionable:VOLTage:ENABle
query returns a floating number
Range
Default
none
N2, N5PT2, N12
N24, P5STby, P5EXt
MIN, MAX
none
Default
None
power-supply voltage
will return the last measurement made
STAT:QUES:VOLT:LEV? P5, MAX
Description
Indicates which power supply
current is being queried
When added after < supply >,
queries the maximum and
minimum voltage limits.
Description
will return the limit
Chapter 3