History Subsystem - HP E8402A User And Service Manual

Vxi c-size mainframe
Table of Contents

Advertisement

Subsystem
Syntax
Chapter 3
The history subsystem gives access to the enhanced monitor's history-gathering
function.
:HISTory
:BLOWer
[:HISTogram]? < blower >
:CURRent
:CMAXimum? < supply >
[:HISTogram]? < supply >
:MAXimum? < supply >
:POWer
:CMAXimum? < supply >
[:HISTogram]? < supply >
:MAXimum? < supply >
:QUEue
:COUNt?
[:FETCh]? < event index >
:RESet
[:ALL]
:BLOWer < blower >
:CURRent < supply >
:POWer < supply >
:QUEue
:TEMPerature < slot >
:VOLTage < supply >
:TEMPerature
:CMAXimum? < slot >
:CMINimum? < slot >
[:HISTogram]? < slot >
:MAXimum? < slot >
:MINimum? < slot >
:TIME
:LCALibration?
:LHReset?
:LTST?
:ON?
:OPERating?
:UNITs
[:TIME]< unit >
[:TIME]?
:VOLTage
:CMAXimum? < supply >
:CMINimum? < supply >
[:HISTogram]? < supply >
:MAXimum? < supply >
:MINimum? < supply >

HISTory Subsystem

Returns <blower> histogram data
Returns max. < supply > current since pwr-on.
Returns < supply > current histogram data
Returns maximum < supply > current.
Returns max. < supply > power since pwr-on.
Returns < supply > power histogram data.
Returns maximum < supply > power.
Returns number of events in history queue.
Returns < number > history event from queue.
Resets data in history subsystem to zero.
Resets data in < blower > history to zero.
Resets data in < supply > current history to zero.
Resets data in < supply > power history to zero.
Erases all data in history queue.
Resets the data in < slot > history to be zero.
Resets data in < supply > voltage history to zero.
Returns max. < slot > temperature since pwr-on.
Returns min. < slot > temperature since pwr-on.
Returns for < slot > histogram data.
Returns maximum < slot > temperature.
Returns minimum < slot > temperature.
Returns hr, min, sec since last calibration.
Returns hr, min, sec since last history reset.
Returns hr, min, sec since last *TST.
Returns hr, min, sec since power-on.
Returns time mainframe has been operating.
Sets time units for history subsystem.
Returns time units for history subsystem.
Returns max. < supply > voltage since pwr-on.
Returns min. < supply > voltage since pwr-on.
Returns < supply > voltage histogram data.
Returns maximum < supply > voltage.
Returns minimum < supply > voltage.