History:temperature:cmaximum? <Slot> History:temperature:cminimum? <Slot - HP E8402A User And Service Manual

Vxi c-size mainframe
Table of Contents

Advertisement

HISTory:TEMPerature:CMAXimum? < slot >
HISTory:TEMPerature:CMINimum? < slot >
Parameters
Returned Data
Comments
Error Conditions
Reset Condition
Related
Commands
76 Programming the Enhanced Monitor
HISTory:TEMPerature:CMAXimum?
for the maximum temperature measured by the Enhanced Monitor for the <slot>
parameter since power-on of the mainframe.
HISTory:TEMPerature:CMINimum?
for the minimum temperature measured by the Enhanced Monitor for the <slot>
parameter since power-on of the mainframe.
Name
Type
< slot >
enum.
OUT0...OUT12,
DELTa0...DELTa12,
AMBient
Type
Range
float
These maximums/minimums can be reset by powering the mainframe off and
then powering it back on.
The following table lists the most common error conditions and causes. Error
numbers and corresponding messages can be found using
Number
Message
-109
"Missing parameter"
-224
"Illegal Parameter"
A *RST has no effect on the HISTory subsystem.
HISTory:TEMPerature:MAXimum?, HISTory:TEMPerature:MINimum?,
HISTory:TEMPerature:[HISTogram]?
<slot> returns a single floating point number
<slot> returns a single floating point number
Range
Default
none
Minimum or maximum temperature.
You must include the < slot > parameter.
The <slot> parameter was not correct.
Description
Exhaust temperature for slots 0 - slot
12
Temperature change above the
ambient temperature for slots0 - slot
12
Entrance air temperature
Description
SYSTem:ERRor?
Probable Cause
query.