Chapter 3. Configuration
Trap Type
Yellow Alarm (RAI)
Blue Alarm (AIS)
Idle Signal
Eqpt. Fail NSA
Eqpt. Fail SA
Com. Eqpt. Fail NSA when the unit receives indication from the network
Trap Type
Cold Start
Link Up
Link Down
Auth. Failure
62
Table 3-6. Far End Alarm Trap Descriptions (Continued)
If ENABLED, this trap is sent...
when the unit receives indication from the far end
unit through the FEAC channel that the far end
unit is receiving an RAI indication from the
network.
when the unit receives indication from the far end
unit through the FEAC channel that the far end
unit is receiving an AIS indication from the
network.
when the unit receives indication from the far end
unit through the FEAC channel that the far end
unit is receiving an idle signal (1100) over the
entire DS3 payload.
when the unit receives indication from the network
through the FEAC channel of a non-service-
affecting failure in the network equipment.
when the unit receives indication from the network
through the FEAC channel of a service-affecting
failure in the network equipment.
through the FEAC channel of a non-service-
affecting failure in the network common
equipment.

Table 3-7. MIB II Standard Trap Descriptions

If ENABLED, this trap is sent...
when the unit is first powered on.
when the network recovers from a Link Down
condition and data transmission is restored.
when a network condition prevents data
transmission. This could be either an alarm or a
network test.
when an SNMP request is made with the wrong
read or write community names.
T3SU 300 User Manual
61202217L1-1B