Table 3-6. Mib Ii Standard Trap Descriptions; Table 3-7. Network Trap Descriptions; Table 3-8. Dte Port Trap Description; Table 3-9. Quad Dsx Port Trap Description - ADTRAN T3SU 300 User Manual

A multiport dsu/csu (data service unit/channel service unit) that provides access to t3 services
Hide thumbs Also See for T3SU 300:
Table of Contents

Advertisement

Trap Type
Cold Start
Link Up
Link Down
Auth. Failure
Trap Type
Network Test In
Network Test Out
Trap Type
Port Status Change
Trap Type
QDSX Alarms
Toggle All Traps
When activated, this entry allows you to toggle ALL alarms
(previously described) between their disabled and enabled states.
61200217L1-1

Table 3-6. MIB II Standard Trap Descriptions

If ENABLED, this trap is sent...
when the unit is first powered on.
when the network recovers from a Link Down
condition and data transmission is restored.
when a network condition prevents data
transmission. This could be either an alarm or a
network test.
when an SNMP request is made with the wrong
read or write community names.

Table 3-7. Network Trap Descriptions

If ENABLED, this trap is sent...
when the unit goes into a DS3 network test, either
commanded locally or remotely.
when the unit is in a DS3 network test and the test
is terminated.

Table 3-8. DTE Port Trap Description

If ENABLED, this trap is sent...
when the unit detects a change in any of the four
DTE ports. These traps may be generated when
a DTE interface card is plugged in, a cord is
removed, a port is reconfigured, a port goes into
an error condition due to cabling problems, or a
port goes into a test mode.

Table 3-9. Quad DSX Port Trap Description

If ENABLED, this trap is sent...
when any of the DSX-1 ports detects an error
condition.
T3SU 300 User Manual
Chapter 3. Configuration
3-19

Advertisement