Optional Specifications - YOKOGAWA Dpharp vigilantplant EJA110A User Manual

Differential pressure transmitters
Hide thumbs Also See for Dpharp vigilantplant EJA110A:
Table of Contents

Advertisement

10.3 Optional Specifications

For F
Fieldbus explosion protected type, see IM 01C22T02-01E.
OUNDATION
For PROFIBUS PA explosion protected type, see IM 01C22T03-00E.
Item
Factory Mutual (FM)
CENELEC ATEX
FM Explosionproof Approval
Explosionproof for Class I, Division 1, Groups B, C and D
Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G
Hazardous (classified) locations, indoors and outdoors (NEMA 4X)
Temperature class: T6
Amb. Temp.: –40 to 60 C (–40 to 140 F)
FM Intrinsically safe Approval
Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1,
Groups E, F & G and Class III, Division 1 Hazardous Locations.
Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division. 2,
Groups E, F & G, and Class III, Division 1 Hazardous Locations.
Enclosure: "NEMA 4X", Temp. Class: T4, Amb. Temp.: –40 to 60 C (–40 to 140 F)
Intrinsically Safe Apparatus Parameters
[Groups A, B, C, D, E, F and G]
Vmax=30 V, Imax=165 mA, Pmax=0.9 W, Ci=22.5 nF, Li=730 H
[Groups C, D, E, F and G]
Vmax=30 V, Imax=225 mA, Pmax=0.9 W, Ci=22.5 nF, Li=730 H
Combined FF1 and FS1
CENELEC ATEX (KEMA) Flameproof Approval
Certificate: KEMA 02ATEX2148
II 2G EExd IIC T4, T5, T6
Amb. Temp.: T5; –40 to 80 C ( –40 to 176 F), T4 and T6; –40 to 75 C ( –40 to 167 F)
Max. process Temp.: T4; 120 C (248 F), T5; 100 C (212 F), T6; 85 C (185 F)
CENELEC ATEX (KEMA) Intrinsically safe Approval
Certificate: KEMA 02ATEX1030X
II 1G EEx ia IIC T4, Amb. Temp.: –40 to 60 C (–40 to 140 F)
Ui=30 V, Ii=165 mA, Pi=0.9 W, Ci=22.5 nF, Li=730 H
Combined KF2, KS2 and Type n
Type n
II 3G Ex nL IIC T4, Amb. Temp.: –40 to 60°C (–40 to 140°F)
Ui=30 V DC, Ci=22.5 nF, Li=730 μH
Dust
II 1D maximum surface temperature T65°C (149 F) {Tamb.: 40°C (104 F)},
T85°C (185 F) {Tamb.: 60°C (140 F)}, T105°C (221 F) {Tamb.: 80°C (176 F)}
*1:
Applicable for Electrical connection code 2 and 7 (1/2 NPT female).
*2:
Applicable for Electrical connection code 2, 4, 7 and 9 (1/2 NPT and M20 female).
Description
*1
*1
*1
*2
*2
10-6
10. GENERAL SPECIFICATIONS
*2
Code
FF1
FS1
FU1
KF2
KS2
KU2
T1008-1.EPS
IM 01C21B01-01E

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dpharp eja120aDpharp eja130a

Table of Contents