3-14. Connecting the pneumatic components (Pneumatic type only)

[Connection common to all areas]
When using the air-driven type model, connect the pneumatic components as described below.
1
7
8
3) Install solenoid valve asm. 8 on solenoid
valve installing plate 6 in the direction as
shown in the figure, using screw 7 supplied as
accessories.
!2
6
3
2
4
5
6
!1
!3
Table
!1
– 14 –
1) Install regulator 1 to installing plate 2 , and
install it to the stand with screw 3 , washer 4
and nut 5 .
2) Connect the cord coming from the regulator
with CN78 (air relay cable).
(Refer to
"!-3-11. [Wiring diagram of circuit board]"
p.11.)
!0
9
4) Fix the air tube using cable clip 9 supplied with
the machine as accessories. (For the setscrew,
use setscrew !0 fixing the motor cover.)
5) Install solenoid valve installing plate A asm. !1
on the table with two setscrews !3 .
Connect solenoid valve installing plate A
asm !1 and regulator 1 with long air tube !2
supplied as accessories with the machine.
Attach the relevant components referring to the
illustrations.