HP TR3271 Programming Manual page 88

Management programming manual
Table of Contents

Advertisement

COMMANDS AND RESPONSES
ALTER Command
ZMULTI-BLOCK
ZOFFLINE-TIMER
ZPROG
ZREAD-CMD
6-24
%value
If the value of this field is any
16-bit octal value other than 0,
%177776, or %177777, the TR3271
subsystem responds with a RVI.
value in this field is interpreted
as IBM Status/Sense information.
The TR3271 subsystem will send these
bytes to the host when the host,
after receiving the RVI, polls the
subsystem.
correct format.
in the Device-Specific Access
Methods--AM3270/TR3271 for a list
of appropriate values.
A Boolean variable that specifies whether the
TR3271 subsystem supports multiple block trans-
missions.
If the value is ZSPI-VAL-TRUE, the
subsystem supports multiple block transmissions;
if the value is ZSPI-VAL-FALSE, it does not.
default is ZSPI-VAL-FALSE.
A timestamp that specifies the period of time,
in .01 seconds, that the TR3271 subsystem waits
to receive a signal from the host.
TR3271 subsystem does not receive anything within
this interval, the host is considered down and a
timeout error is reported.
the 0 through 5:27:67 range.
wait forever.
A 32-byte file name that identifies the program
file that is to be downloaded to the CLIP.
default is $SYSTEM.CSS00.C9315P00.
An enumerated value that specifies whether the
TR3271 subsystem accepts the Read Buffer and
Read Modified command from the host.
ZTR3-VAL-READ-NONE causes the subsystem to reject
the Read Buffer and Read Modified commands.
value ZTR3-VAL-READ-ALL causes the subsystem to
accept both the Read Buffer and Read Modified
commands.
ZTR3-VAL-READ-RDMOD causes the subsys-
tem to accept the Read Modified command, but
reject the Read Buffer command.
The Read Buffer command is supported only for
CRT subdevices.
specifies the ZTR3-VAL-READ-ALL for PTP
subdevices, Read Buffer commands are rejected.
This restriction is imposed by the protocol used
by PTP subdevices.
field is ZTR3-VAL-READ-NONE.
The value must be in the
Refer to Appendix C
The value must be in
The default is 0,
If your management application
The default value for this
The
The
If the
The
The value
The

Advertisement

Table of Contents
loading